Power Generation Equipment

Diesel Generator

Generator-50Hz

  • Rated output: 2 to 2,000kW/2 to 2,500kVA
  • Rated voltage: L-N 110 to 277V, L-L 220 to 480V
  • Rated frequency: 50/60Hz
  • Powered by reliable engines
  • Branded alternator
  • Open type, silent type, or super silent type generator
  • ISO, CE certified
  • High output
  • Compact and light weight
  • High level of trust in the global market

 

Learn More

Uninterruptible Power Supply (UPS)

EA660 50-600 KVA

  • High efficiency 96.5%
  • High power factor (>o.99) and THDi <3%
  • Power flexibility from 50 – 600 kW
  • High MTBF and low MTTR
  • High adaptability
  • Self-aging function, easy debugging and test on site
  • Modular hot-swappable & scalability
  • DSP digital control technology

EA890 80-500 KVA

  • High efficiency even at light loads
  • High power factor (>0.99) and low THDi
  • Power flexibility from 80 – 500 kW
  • High MTBF and Low MTTR
  • Strong mixed load capacity and high overload capacity
  • Batteries are connected directly to the bus, improving the impact resistance of UPS output
  • Online double-conversion with DSP control

EA990 Super 200-1200 KVA

  • High efficiency up to 96.8%
  • Input power factor up to 0.99, THDi <3%
  • Power flexibility from 200 – 1200 kW
  • Online double conversion architecture with strong load capacity
  • Self-aging function to simplify debugging and test on site
  • Share battery pack in parallel operation, saving user’s battery cost
  • Multi-DSP design that ensures fast and reliable control and switching

Load Bank

2000 kw Resistive Load Bank

with Generator Tester for Generator Testing

  • Type of load: Resistive, PF = 1.0
  • Rated testing voltage: AC 3P4W, 110-480 VAC
  • Rated frequency: 50/60 Hz
  • Testing capacity: from 0kw to the max
  • Parameter measuring accuracy grade: 0.3
  • Load control accuracy: ± 5%
  • Protections: Over heating, cooling fans failure, and over load

800 kw Resistive load bank

for Generator Testing

  • Type of load: Resistive, PF = 1.0
  • Rated testing voltage: 110-480 VAC
  • Rated frequency: 50/60 Hz
  • Testing capacity: from 0kw to the max
  • Parameter measuring accuracy grade: 0.5
  • Load control accuracy: ± 3%
  • Protections: Over heating, cooling fans failure, and over load

125-2500 kva Inductive Load Bank

  • Type of load: Inductive, PF = 1.0
  • Rated testing voltage: AC 3P4W, 110-480 VAC
  • Rated frequency: 50/60 Hz
  • Testing capacity: 125-2500 kva
  • Parameter measuring accuracy grade: 0.5
  • Load control accuracy: ± 3%
  • Protections: Over heating, cooling fans failure, and over load

1250 kva Resistive and Inductive

Load Bank with Generator Tester

  • Type of load: Resistive, PF = 1.0
  • Rated testing voltage: AC 3P4W, 110-480V
  • Rated frequency: 50/60 Hz
  • Testing capacity: from 0kw to the max
  • Parameter measuring accuracy grade: 0.3
  • Load control accuracy: ± 5%
  • Protections: Over heating, cooling fans failure, and over load